TotalRecoveryEfficiency

help

Description

The net total energy (sensible plus latent, also called enthalpy) recovered by the supply airstream adjusted by electric consumption, case heat loss or heat gain, air leakage and airflow mass imbalance between the two airstreams, as a percent of the potential total energy that could be recovered plus the exhaust fan energy. Values for some products can be found at the Home Ventilating Institute (hvi.org).

help
Data Type
xs:double
Min Occurances
0
Max Occurances
1
Max Inclusive
1
Min Exclusive
0
help

Attributes

  • dataSource
    • Data Type: string
    • Enumeration: software
    • Enumeration: user
help

Use Cases / Standard Data Sets

  • Audit
  • Upgrade
  • Home Energy Score
  • Home Performance Certificate (BPI-2101)