help

Description

The Leakage Area is defined in TECBLAST as the size of a sharp edged orifice which would leak at the same flow rate as the measured leakage, if the orifice were subjected to the Test Pressure. Leakage Area [sq in] = Duct System Leakage Rate [CFM] / (1.06 * (Test Pressure [Pa]) ^ 0.5)

help
Data Type
xs:double
Min Occurances
0
Max Occurances
1
Min Exclusive
0
help

Attributes

  • dataSource
    • Data Type: string
    • Enumeration: software
    • Enumeration: user
help

Use Cases / Standard Data Sets

  • Audit
  • Upgrade
  • Home Energy Score
  • Home Performance Certificate (BPI-2101)
help